Главная > Unit of corrosion rate indicating plates BLI-2

Unit of corrosion rate indicating plates BLI-2

Тел.:+7 (495) <i>645-29-15</i>, факс: <i>645-29-16</i>

info@energofin.ru

Unit of corrosion rate indicating plates BLI-2


Purpose

  • Unit of corrosion rate plates-indicators designed for definition of corrosion danger and efficiency of action of electrochemical protection against corrosion of the underground steel structures
  • The essence of the method is that by means of the set of indicating plates with different thickness total corrosion is additionally estimated and order of its average rate during electrochemical protection of the pipeline in the place of installation of the set of indicating plate by time from the moment of its installation till the loss of series electrical conductivity of the plates as a result of corrosion.

Features

  • The unit is an article of one-time use; in the course of operation it is not subject to reconstruction or repair.

Operation conditions

  • The unit provides reliable and stable operation in all macroclimatic districts in the terms of effect of the following climatic factors:

— Upper value of the environment temperature +100C;

— Lower value of the environment temperature -40C;

— Upper value of relative humidity 100% at the temperature 35C;

  • Category of location of the units – 5 by GOST 15150-69.